SC/APC Duplex Fiber Adapter, Single-Mode, Green, 8°, Ceramic Sleeve, Flanged (FOS-SCA-D)
Couldn't load pickup availability
This is a duplex SC/APC fiber adapter for single-mode, the green coupler that joins two pairs of SC/APC connectors end to end through a panel, with the transmit and receive fibers side by side. It's a plastic housing with integrated flanges and a snap-in body in the standard SC duplex footprint, so it drops into the duplex SC cutout on a fiber distribution pedestal, a fiber distribution unit, a patch panel, or a wall-mount enclosure without tools. Each port has a ceramic alignment sleeve, and the housing is green, which is the color code for the 8° angled polish that keeps back reflection low on PON, CATV, RFoG, WDM, and other links that can't tolerate light bouncing back toward the transmitter. It takes SC/APC connectors only, on OS1 or OS2 single-mode fiber; a blue SC/UPC connector has a flat end-face and doesn't mate with an angled one. It comes with metal clips and dust caps, it's RoHS compliant, and it's sold individually. For a plate already loaded with these, the FAP-SM-SCA-6D with six or the FAP-SM-SCA-3D with three; for one fiber per adapter, the simplex FOS-SCA-S; for the cords, the duplex SCASCASM, the simplex SCASCASMP for a PON drop, and the LCASCASM for SC/APC to an LC/APC port; for the pigtails behind the panel, the PGTSC12-SMA and PGUSC12-SMA; for the blue UPC version of this adapter, the FOS-SCU-D.
Features
- Duplex SC/APC. Two SC ports, single-mode, 8° angled polish, green.
- Ceramic alignment sleeves. Low insertion loss and very low back reflection on both ports.
- SC duplex footprint. Fits the standard duplex SC cutout in any panel, pedestal, FDU, or enclosure.
- Flanged, snap-in. Plastic housing with integrated mounting flanges; no tools.
- OS1 and OS2. For SC/APC connectors only; not for SC/UPC.
- Metal clips and dust caps included.
- RoHS compliant.
- Sold individually.
Where It Fits
It suits a fiber distribution pedestal or an outside-plant FDU on an APC plant where single-mode circuits are patched in pairs on SC and the enclosure's cutouts are duplex. It suits a CATV or RF-over-fiber head end where the forward and return paths run on two fibers and a reflective UPC adapter would put noise in the picture, and a WDM shelf where the return loss spec rules UPC out. Installers loading a blank LGX plate or an FDU port by port on an APC plant use it, and so do techs replacing a worn duplex adapter in an existing green panel without changing the plate. A PON head end where the OLT uplinks or the inter-office links run as two-fiber circuits on SC/APC is a candidate. It goes with the SC/APC patch cords from the single-mode patch cable collection, with the SC/APC pigtails and adapter plates from the fiber panel collection, and with the fiber cleaners from the test equipment collection. For a plate loaded with these, the FAP-SM-SCA-6D or FAP-SM-SCA-3D. For single fibers, the simplex FOS-SCA-S. For the cords, the SCASCASM, and for SC/APC to LC/APC, the LCASCASM. For a cord from an APC panel to a UPC port, the SCUSCASM. For the pigtails, the PGTSC12-SMA and PGUSC12-SMA. For a UPC plant, the FOS-SCU-D.
Good to Know
Green means APC, and it's a hard rule, not a color preference: an 8° angled ferrule against a flat UPC ferrule leaves an air gap at the end-face, which costs a few dB and sends a reflection back up the fiber, so every connector that goes into this adapter has to be green SC/APC, and the cord at the other end of each port has to match whatever it plugs into. The ceramic sleeve is the right sleeve for single-mode; a phosphor bronze sleeve is a multimode part and doesn't hold a 9 µm core to the tolerance a single-mode link needs. Duplex or simplex is the choice between this adapter and the FOS-SCA-S: a duplex adapter holds a transmit-and-receive pair side by side and keeps polarity for you, which is what a two-fiber circuit wants, while a PON or FTTH drop runs both directions on one fiber and takes the simplex adapter. Keep the A and B fibers in the right positions on both sides so the polarity comes out as the as-built says. The snap-in flanges are what hold it in a stamped cutout, and the metal clips in the box are for plates that take a clip rather than a flange, so check which the panel wants before you order a quantity. Clean and inspect every ferrule before it goes in, since an APC end-face shows dirt as loss and reflection just like any other, and leave the dust caps in any port without a cord. Don't look into an open port on a live link; a CATV or PON port carries a laser whether or not anything is on the other end.
Specifications
| Spec | Detail |
|---|---|
| Model | FOS-SCA-D |
| Series | FOS |
| Type | Fiber optic adapter, duplex SC |
| Polish | APC, 8° |
| Fiber Type | Single-mode, OS1 and OS2 |
| Color | Green |
| Alignment Sleeve | Ceramic |
| Housing | Plastic, integrated flanges, snap-in |
| Footprint | SC duplex |
| Compatibility | SC/APC connectors only; not for SC/UPC |
| Compliance | RoHS |
| Quantity | Sold individually, with metal clips and dust caps |