SC/UPC-LC/UPC Single-mode Fiber Optic Launch Cable - 1000M (FLC-1001)

SKU: FLC-1001 UPC: 810053351871
Regular price $274.95
Payment methods
  • Ach Direct Debit
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Ships direct from the manufacturer — please allow up to 10 business days, though it often ships sooner, then goes out via the shipping service you select at checkout. This item does not ship from our warehouse, so delivery times may vary.

Ships direct from the manufacturer. Please allow up to 10 business days, though it often ships sooner.

An OTDR can't see the first connector on a link, because that connector sits inside the instrument's own dead zone, and the fix is to put a known length of fiber between the OTDR and the link so the first event lands where the trace can resolve it. The Jonard Tools FLC-1001 is that length for UPC networks: 1,000 m (3,281 ft) of G.657.A2 single-mode fiber wound in a compact housing, with armored pigtails terminated SC/UPC on one end and LC/UPC on the other, so it connects to an OTDR with either port and to an SC or LC panel without an extra adapter. The fiber is bend-insensitive G.657.A2, with attenuation of 0.35 dB/km or less at 1310 nm and 0.22 dB/km or less at 1550 nm, connector loss of 0.1 dB or less, and return loss of 55 dB or more at the UPC connectors, so the launch cable adds a clean, known section to the trace rather than events of its own. The polish type is color coded for identification, a shoulder strap carries it, and a magnet on the bottom of the housing sticks it to a fiber rack or a cabinet while you test. For APC networks, the FLC-1006 and FLC-1007 are the same cable with APC ends.

Features

  • 1,000 m of single-mode fiber. 3,281 ft of G.657.A2, long enough to clear the dead zone on most OTDR testing, including long pulse widths.
  • SC/UPC one end, LC/UPC the other. One connector type on each end, so the same launch cable fits an SC-port OTDR and an LC-port OTDR, or an LC panel and an SC panel.
  • Armored pigtails. Steel interlocked armor under the fiber jacket protects the fiber from accidental damage.
  • Low loss, high return loss. ≤0.35 dB/km at 1310 nm, ≤0.22 dB/km at 1550 nm, ≤0.1 dB per connector, and ≥55 dB return loss at the UPC connectors.
  • Color-coded polish. The UPC connectors are color coded for quick identification, so a UPC pigtail never ends up in an APC port.
  • Compact housing, strap, and magnet. Shoulder strap for carrying, and a magnet on the bottom of the housing that mounts it to a fiber rack or cabinet while you test.

Where It Fits

It suits enterprise, campus, and data center teams testing UPC backbone, riser, and trunk fiber, where the panels are LC and the OTDR port is SC, or the reverse, central office and metro work on UPC-terminated single-mode, contractors who have to hand over OTDR traces where the first and last connectors are measured rather than hidden, anyone with a UPC-port OTDR testing a UPC network who wants one launch cable that fits both connector types, and the OTDR-1000 or any other OTDR, which needs a launch cable to do its job on a short link and a receive cable to see the far end.

Good to Know

Connect the launch cable between the OTDR and the near end of the link, so the OTDR's own dead zone falls inside the launch fiber and the link's first connector shows up as a measurable event; set the OTDR's launch-cable length to 1,000 m so it subtracts the launch fiber from the distances it reports. For the far-end connector to be measured too, put a second launch cable (a receive cable) on the far end, which is the usual reason to own two. The connectors are UPC; mate them only to UPC ports and UPC connectors, since UPC into APC damages both end faces and shows up as a huge reflection on every trace afterward, and the color coding is there to stop that. If the network is APC, which most PON and FTTH plant is, this isn't the launch cable for it; the FLC-1006, FLC-1007, and the mixed FLC-1005 are. Clean every connector before every mating, including the launch cable's own pigtails and the OTDR port, because a dirty launch cable is a bad event at the start of every trace you take until it's found. Leave the fiber on its housing and don't unwind it; the 1,000 m is a known reference and a kink in it becomes an event. The armor protects the pigtails from being crushed or stepped on, not from being bent tight at the connector; coil them loosely and cap them when they're not connected. For a multimode OTDR a multimode launch cable is needed; this one is single-mode.

Specifications

Spec Detail
Model FLC-1001
Manufacturer Jonard Tools
Type Fiber optic launch cable, single-mode, in housing
Cable Length 1,000 m (3,281 ft)
Fiber Type G.657.A2 single-mode, bend-insensitive
Connector Types SC/UPC (one end), LC/UPC (other end)
Pigtail Length 1.5 m (4.9 ft)
Pigtail Armor Steel interlocked armor under the jacket
Max Insertion Loss, 1310 nm ≤0.35 dB/km
Max Insertion Loss, 1550 nm ≤0.22 dB/km
Connector Insertion Loss ≤0.1 dB
Return Loss ≥55 dB (UPC)
Polish Identification Color coded
Housing Compact, with shoulder strap and bottom magnet for rack mounting
Weight 0.8 lb (363 g)
Shipping Ships direct from the manufacturer, allow up to 10 business days

Documentation

Document Link
Data Sheet Single-mode fiber optic launch cables data sheet (PDF)