Slim RJ45 Plug for 28 to 30 AWG Cat6 and Cat6A Cable, Clear, 25/50/100 Pack (PLG-R45-CT6SL)
Couldn't load pickup availability
Slim patch cable is 28 to 30 AWG under a jacket less than 4 mm across, and a standard RJ45 plug doesn't grip it: the conductors swim in the channels and the strain latch closes on nothing. This slim RJ45 plug is sized for it. It's an 8P8C modular plug with a clear polycarbonate housing and 3-prong contact blades plated with 50 µin of gold, built for solid or stranded Cat6 and Cat6A slim cable with an insulated conductor diameter of 0.64 to 0.70 mm and a cable OD under 3.9 mm, so the conductors seat, the blades bite, and the latch holds. The clear housing lets the pair order be checked before the crimp, and the plug is UL listed and RoHS compliant, rated 250 V AC at 2 A. It comes in packs of 25, 50, and 100 for making custom-length slim patch cords for high-density panels and tight spaces.
Features
- For slim Cat6 and Cat6A cable. 28 to 30 AWG, solid or stranded; insulated conductor 0.64 to 0.70 mm; cable OD under 3.9 mm.
- 8P8C, 3-prong contacts. Copper alloy blades with 50 µin gold plating.
- Clear polycarbonate housing. UL94V-2; the pair order is visible before the crimp.
- 20 lb cable-to-plug tensile strength.
- UL listed, RoHS compliant. 250 V AC at 2 A; 500 V AC dielectric withstand.
- Packs of 25, 50, and 100.
Where It Fits
It suits data center and network techs making custom-length slim patch cords for a 48-port switch where standard cable won't fit the cable manager, structured cabling crews terminating bulk slim Cat6 and Cat6A to length instead of stocking every pre-made size, AV and rack builders dressing a tidy run of short jumpers between a patch panel and a switch, anyone who has crimped a standard plug onto slim cable and watched the conductors slide, and a job that already has the bulk slim Cat6 and Cat6A cable, the RJ45 crimp tool, and the keystone jacks and couplers from the copper collections. For standard 23 to 24 AWG cable, a standard Cat6 or Cat6A RJ45 plug; for the jacks at the other end of the cord, the KEY6-90 and MIG6A-90.
Good to Know
Measure the cable before ordering: this plug is for conductors insulated to 0.64 to 0.70 mm and a jacket under 3.9 mm, which is slim 28 to 30 AWG cable, and a standard 23 or 24 AWG Cat6 conductor won't go into the channels. The 3-prong contact is the one that works on stranded conductors and on the small solid conductors of slim cable, which is why the plug takes both; a 2-prong plug is for solid only. Strip, untwist as little as possible, hold the T568B order, and look through the clear housing to check it before the tool closes, since the crimp can't be undone. Use a crimp tool with a standard RJ45 die; the plug's blades are standard height, so a tool that's right for ordinary plugs is right for this one. Slim cable is more flexible and less robust than standard cable, so support a cord that hangs, keep the bend radius generous at the plug, and expect a 28 AWG cord to be a patch cord, not a horizontal run: the length limit for 28 AWG under the TIA guidance is shorter than for 24 AWG, and PoE at full power warms a 28 AWG bundle more than a 24 AWG one, so keep slim cords short and unbundled where the loads are heavy. The housing is polycarbonate with no metal shell, so it's for unshielded cable; shielded slim cable needs a shielded plug.
Specifications
| Spec | Detail |
|---|---|
| Model | PLG-R45-CT6SL25 (25 pack; 50 and 100 packs by suffix) |
| Series | PLG-R45 |
| Type | RJ45 modular plug, 8P8C, slim |
| Cable | Cat6 and Cat6A slim, 28 to 30 AWG, solid or stranded |
| Conductor Insulation Diameter | 0.64 to 0.70 mm (0.025 to 0.0276 in) |
| Cable OD | Under 3.9 mm |
| Contacts | 3 prong, copper alloy, 50 µin gold plating |
| Housing | Polycarbonate, UL94V-2, transparent |
| Electrical Rating | 250 V AC max at 2 A (UL) |
| Dielectric Withstand | 500 V AC |
| Insulation Resistance | 100 MΩ |
| Termination Resistance | 20 mΩ max after environmental testing |
| Cable-to-Plug Tensile Strength | 20 lb min |
| Durability | 200 mating cycles |
| Operating Temperature | −20 to 50 °C |
| Compliance | UL listed, RoHS |
| Quantity | Packs of 25, 50, and 100 |