CAT6A Shielded RJ45 Field Termination Plug - 10G (CAT6ASH-PLG)
Couldn't load pickup availability
This is a shielded Cat6A RJ45 field termination plug for shielded solid or stranded 23 to 26 AWG cable with a jacket of 5.6 to 8.5 mm. It terminates without a crimp tool. The conductors go into a wire alignment insert in T568A or T568B order, the insert pushes into the plug, and the IDC contacts cut through the insulation as the body closes, so the only tool you need is a cable stripper. It meets the Cat6A performance requirements of ANSI/TIA-568.2-D for 10 Gigabit Ethernet and it supports PoE++ (802.3bt, 4PPoE) up to 100 W. The housing is zinc die-cast with nickel plating, with a grounding contact of the same metal, the contacts are phosphor bronze with 50 µin of gold over nickel, and strain relief boots are included. It's sold individually. For the jack at the other end of the link, the MIG6A-SHD or KEY6-SHD; for Cat8 cable, the CAT8SH-PLG is the same plug in its Cat8 version; for a crimp-style shielded Cat6A plug, the PLG-R45-CT6AS.
What's in the Box
- Shielded Cat6A RJ45 plug with wire alignment insert
- Strain relief boots
Features
- Cat6A, 10 Gigabit. Meets Cat6A performance requirements per ANSI/TIA-568.2-D.
- Tool-less termination. Wire alignment insert and IDC contacts; no crimp tool, a cable stripper is recommended.
- PoE++ to 100 W. 802.3bt 4PPoE; rated for PoE power transfer.
- For shielded 23 to 26 AWG cable, solid or stranded. Cable OD 5.6 to 8.5 mm; T568A and T568B wiring.
- Zinc die-cast housing, nickel plated. Shielded, with a nickel-plated die-cast grounding contact.
- 50 µin gold-plated contacts. Phosphor bronze with 100 µin nickel underplate.
- Re-terminable. IDC rated for a minimum of 20 installation cycles; 750 mating cycles.
- Strain relief boots included.
Where It Fits
It suits data center and network techs building shielded Cat6A patch cords to length for 10GBASE-T switch and server ports where a factory cord isn't the right length, structured cabling crews terminating shielded bulk Cat6A in a plant that runs S/FTP or F/UTP end to end, anyone running 802.3bt power to a high-draw device over shielded cable and wanting a plug that's rated for it, industrial and plant networks that shield against the VFDs and the welders, installers who'd rather re-terminate an IDC plug than cut off a crimped one, and a job that already has the shielded bulk Cat6A, the shielded keystone jacks and panels, and a cable stripper from the copper collections. For the jacks and panels, the MIG6A-SHD and KEY6-SHD; for a wrap of extra copper under the shield clamp, the FOIL-001 strips; for Cat8, the CAT8SH-PLG; for a crimp-style plug, the PLG-R45-CT6AS.
Good to Know
Measure the cable before ordering: this plug is for 23 to 26 AWG conductors under a 5.6 to 8.5 mm jacket, which is a wide range and covers nearly all shielded Cat6A, thick-jacketed outdoor and industrial cable included. Strip the jacket, fold the braid or foil back over it where the shield clamp lands, lay the conductors into the insert in T568A or T568B (the same at both ends), trim them flush, and close the plug; the IDC contacts cut the insulation as the body closes, so don't strip the individual conductors. The plug can be opened and re-terminated a minimum of 20 times, which is what tool-less buys you over a crimp. A shielded plug only shields if the shell is bonded to the cable's shield and the jack at the other end is shielded too, so use shielded jacks and panels throughout, and bond the shield at one end only unless the two ends share a ground. At 100 W of PoE++, keep the bundle loose and the cords short, and never unplug under load, since the arc on break lands on the contacts. The boots are included, so there's nothing to slide on before termination; fit the boot that matches your jacket. The insertion force is 30 N max and the plug-to-jack retention is 7.7 kg, so a cord that pulls out of a jack is a worn jack, not a loose plug.
Specifications
| Spec | Detail |
|---|---|
| Model | CAT6ASH-PLG |
| Series | CAT6ASH |
| Type | RJ45 field termination plug, 8P8C, shielded, tool-less IDC |
| Category | Cat6A, per ANSI/TIA-568.2-D |
| Cable | Shielded Cat6A, 23 to 26 AWG, solid or stranded |
| Cable OD | 5.6 to 8.5 mm |
| Wiring | T568A or T568B |
| PoE | PoE++ (802.3bt) 4PPoE, up to 100 W |
| Contacts | Phosphor bronze, 100 µin nickel, 50 µin gold min |
| IDC Terminals | Titanium copper, tin plated |
| Housing | Zinc die-cast, nickel plated |
| Grounding Contact | Zinc die-cast, nickel plated |
| Plastics | UL94V-2 (extractor, wire management bar, IDC housing, boots) |
| Boot | Transparent, UL94V-2, included |
| Dimensions | 13.8 mm W × 18.4 mm H front, 14.45 mm H rear × 63.1 mm L (with boot) |
| Insertion Force | 30 N max |
| Retention Strength | 7.7 kg, jack to plug |
| Durability | 750 mating cycles min |
| Installation Cycles | 20 min |
| Operating Temperature | −10 to 60 °C |
| Quantity | Sold individually |