Shielded Cat6A RJ45 Plug for Solid or Stranded Cable, Cable OD to 8 mm, 25/50/100 Pack (PLG-R45-CT6AS)

SKU: PLG-R45-CT6AS25
Regular price $17.75
Pack Size
Payment methods
  • Ach Direct Debit
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Shielded Cat6A cable is thick, its conductors are big, and the shield has to end somewhere that connects to the plug's shell, which is why an unshielded plug won't do. This shielded Cat6A RJ45 plug is built for it. It's an 8P8C modular plug with a copper alloy shield shell, a clear polycarbonate housing, and 50 µin gold-plated contacts, sized for solid or stranded 22 to 26 AWG cable with an insulated conductor of 1.05 to 1.15 mm and a jacket up to 8.0 mm, and its shield termination and strain relief close in one step with the crimp. It meets the Cat6A performance requirements of ANSI/TIA-568-B.2-10 for 10 Gigabit Ethernet, the clear housing lets the pair order be checked before the tool closes, and an optional slim boot adds strain relief and latch protection. It comes in packs of 25, 50, and 100 for making shielded Cat6A patch cables where high-density routers and switches are the norm. For slim 28 to 30 AWG cable, the PLG-R45-CT6SL unshielded slim plug.

Features

  • Shielded Cat6A, 10 Gigabit. Meets Cat6A performance requirements per ANSI/TIA-568-B.2-10.
  • For 22 to 26 AWG cable, solid or stranded. Insulated conductor 1.05 to 1.15 mm; wire OD under 1.2 mm; jacket OD under 8.0 mm.
  • One-step shield termination and strain relief. The crimp closes the shield and the strain relief together.
  • Copper alloy shield shell. 8P8C with copper alloy contact blades and 50 µin gold plating.
  • Clear polycarbonate housing. UL94V-2; the pair order is visible before the crimp.
  • Optional slim boot. Integrated strain relief and latch protection.
  • 20 lb cable-to-plug tensile strength. 250 V AC at 2 A; RoHS compliant.
  • Packs of 25, 50, and 100.

Where It Fits

It suits data center and network techs building shielded Cat6A patch cords to length for 10GBASE-T switch and server ports, structured cabling crews terminating shielded bulk Cat6A in a plant that runs S/FTP or F/UTP end to end, industrial and plant networks that shield everything against the VFDs and the welders, broadcast and AV racks where the Ethernet runs beside power and audio, anyone who has put an unshielded plug on shielded cable and left the drain wire floating, and a job that already has the shielded bulk Cat6A, the RJ45 crimp tool, and the shielded keystone jacks from the copper collections. For the jacks at the other end of the cord, the MIG6A-SHD and KEY6-SHD; for slim unshielded patch cable, the PLG-R45-CT6SL.

Good to Know

A shielded plug only shields if the shell is bonded to the cable's shield and the jack at the other end is shielded too, so fold the foil or braid back over the jacket where the shell's crimp tab lands, make sure the drain wire is under it, and use shielded jacks and patch panels throughout; one unshielded link in the chain turns the shield into an antenna. Measure the cable before ordering: 22 to 26 AWG conductors insulated to 1.05 to 1.15 mm and a jacket under 8.0 mm, which covers most shielded Cat6A, but a 23 AWG cable with thick insulation can run over 1.15 mm and won't seat. Strip, untwist as little as possible, hold the T568B order, and check it through the clear housing before the tool closes, since the crimp can't be undone. Use a crimp tool whose die closes the shield tab as well as the contacts; a plain RJ45 die leaves the shield loose. The boot goes on the cable before the plug, not after. Bond the shield at one end only unless the two ends share a ground, since a shield grounded at both ends in two buildings carries the ground difference as current. Keep the bend radius generous at the plug; shielded Cat6A is stiff and a sharp bend at a plug is where the foil tears.

Specifications

Spec Detail
Model PLG-R45-CT6AS25 (25 pack; 50 and 100 packs by suffix)
Series PLG-R45
Type RJ45 modular plug, 8P8C, shielded
Category Cat6A, per ANSI/TIA-568-B.2-10
Cable Shielded Cat6A, 22 to 26 AWG, solid or stranded
Conductor Insulation Diameter 1.05 to 1.15 mm
Wire OD Under 1.2 mm
Cable Jacket OD Under 8.0 mm
Contacts Copper alloy, 50 µin gold plating
Shield Copper alloy shell
Housing Polycarbonate, UL94V-2, transparent
Boot Optional slim boot with strain relief and latch protection
Electrical Rating 250 V AC max at 2 A (UL)
Dielectric Withstand 500 V AC
Insulation Resistance 100 MΩ
Termination Resistance 20 mΩ max after environmental testing
Cable-to-Plug Tensile Strength 20 lb min
Durability 200 mating cycles
Operating Temperature −20 to 50 °C
Compliance RoHS
Quantity Packs of 25, 50, and 100

Usually ships the same day.