CAT6 Direct Burial Cable 1000ft - Dual Shielded, 23AWG Solid Copper
Ships on a wooden spool. These reels are large and heavy, so shipping costs more than a standard parcel and the shipment requires a receiver who can accept and handle it. Confirm your delivery location can accommodate a shipment of this size and weight before placing your order.
Delivery refusal policy. Because of the size and weight of this item, refused deliveries incur significant freight costs. If a shipment is refused or the receiver cannot accept it, you are responsible for both outbound and return freight, plus any restocking fee.
Couldn't load pickup availability
Optimize outdoor networking with our high-performance CAT6 Dual-Shield Direct-Burial Ethernet Cable, engineered for reliable Gigabit connectivity in demanding underground and exposed environments. Featuring SF/UTP double shielding (100% aluminum-mylar foil plus 30% tinned-copper braid), heavy-duty 23 AWG solid copper conductors, and a rugged UV-resistant LDPE jacket, this 600MHz Cat6 cable provides superior protection against moisture, EMI, and environmental hazards, ideal for long-lasting installations like campus backbones, security cameras, and outdoor Wi-Fi access points.
Designed for maximum protection in the harshest underground conditions, this dual-shielded cable combines the industry's highest level of EMI/RFI immunity with waterproof construction and heavy-duty 23AWG conductors. The double-layer shielding (foil + braid) eliminates both external interference and alien crosstalk, while the thick LDPE jacket resists UV rays, moisture, and soil acids. With 600MHz bandwidth exceeding ANSI/TIA-568.2-D and ISO/IEC 11801 standards, it delivers unmatched reliability for mission-critical underground installations requiring maximum performance and protection.
Key Features
- Dual EMI shielding (SF/UTP): 100% aluminum-mylar foil + 30% tinned-copper braid
- Maximum interference protection - eliminates external EMI/RFI and alien crosstalk
- Ideal for burial near high-voltage power lines or heavy machinery
- Integrated tinned-copper drain wire for superior grounding and static reduction
- Heavy-duty 23 AWG solid bare copper conductors (thicker than standard 24AWG)
- Ultra-low resistance for cooler PoE operations and extended reach
- Reduced attenuation for efficient data transmission over long distances
- HDPE insulation resists water ingress and moisture penetration
- Thick black LDPE jacket withstands UV rays, moisture, and soil acidity
- Temperature-rated for extreme fluctuations (-40°C to +60°C)
- 600MHz bandwidth exceeds ANSI/TIA-568.2-D and ISO/IEC 11801 standards
- Supports 10GBASE-T (short distances), 5GBASE-T, and Gigabit Ethernet
- PoE/PoE+ compatible with extended reach thanks to 23AWG conductors
- Direct burial approved for underground installation
- Sequential footage markers for accurate measurements
- Supplied on sturdy 1000ft wooden spool for tangle-free installation
- Professional-grade for maximum durability and longevity
Ideal Applications
- Direct-burial campus network backbones in high-EMI environments
- Underground runs near high-voltage power lines
- Buried PoE security camera and CCTV installations
- Outdoor Wi-Fi access point connections
- Industrial facility networking with extreme EMI
- Long-distance underground installations
- Critical infrastructure requiring maximum protection
- Medical facilities with sensitive equipment (buried connections)
- Manufacturing plants with heavy machinery
- Data center outdoor interconnections
- Agricultural facilities near electrical systems
- Underground installations requiring both waterproofing and EMI immunity
- Extreme environment deployments
Cable Type & Construction
- Standard: CAT6
- Type: Direct Burial, Outdoor, Dual-Shielded
- Shielding Type: SF/UTP (Screened Foil/Unshielded Twisted Pair)
- Primary Shield: 100% aluminum-mylar foil (around pairs)
- Secondary Shield: 30% tinned-copper braid (outer shield)
- Pairs: 4 twisted pairs
- Total Conductors: 8
- Installation: Direct burial, conduit, outdoor
Conductors
- Gauge: 23 AWG (heavy-duty, thicker than standard 24AWG)
- Material: Solid bare copper
- Configuration: Solid (permanent installation)
- Performance: Ultra-low resistance, extended PoE reach, minimal attenuation
- Advantage: Superior performance over long underground runs
Shielding
- Shield Type 1: 100% aluminum-mylar foil (inner shield around pairs)
- Shield Type 2: 30% tinned-copper braid (outer shield)
- Drain Wire: Yes (tinned copper, integrated)
- Ground Function: Bonds shield to ground, reduces static buildup, prevents packet errors
- EMI/RFI Protection: Maximum - dual-layer protection
- Alien Crosstalk Protection: Excellent
- Best For: Extreme EMI environments, near power lines, industrial underground
Insulation
- Material: High-density polyethylene (HDPE)
- Performance: Resists water ingress, moisture-resistant
- Advantage: Long-term reliability in wet conditions
Performance
- Maximum Frequency: 600MHz (exceeds standard Cat6 550MHz)
- Data Rate: Up to 5GBASE-T (full distance), 10GBASE-T (short distances up to 55m)
- Applications: Gigabit Ethernet (1000BASE-T), Fast Ethernet, 155Mbps TP-PMD/CDDI
- PoE Compatible: Yes - PoE/PoE+ with extended reach due to 23AWG
- Attenuation: Minimized with heavy-duty 23AWG conductors
Jacket
- Material: UV-resistant LDPE (Low-Density Polyethylene)
- Thickness: Extra-thick for maximum protection
- UV Resistance: Superior protection against sunlight degradation
- Moisture Resistance: Excellent waterproofing
- Chemical Resistance: Resistant to soil acidity and environmental contaminants
- Temperature Rating: -40°C to +60°C operating
- Outer Diameter: 7.8mm ± 0.4mm
- Color: Black (typical for burial cable)
- Marking: Sequential footage markers
- Durability: Long-lasting underground performance in extreme conditions
Installation Rating
- Indoor Rated: N/A
- Outdoor Rated: Yes
- Direct Burial: Yes - approved for underground installation
- Suitable Areas: Underground, direct burial, wet locations, conduit, extreme environments
- Environment: Extreme moisture, UV exposure, high-EMI areas, soil contact
Environmental Protection
- Moisture Protection: HDPE insulation + LDPE jacket
- UV Protection: UV-resistant LDPE jacket
- Temperature Range: -40°C to +60°C operating
- Soil Resistance: Resistant to acids and chemicals
- EMI Protection: Dual-layer shielding for maximum interference immunity
- Special Use: Near high-voltage lines, industrial machinery, extreme EMI underground
Design Advantages
- 23AWG Advantage: Lower resistance than 24AWG for better long-distance performance
- Dual Shielding: Maximum EMI/RFI protection available
- Waterproof: HDPE insulation prevents water ingress
- Heavy-Duty: Built for most demanding underground conditions
- PoE Enhanced: Better power delivery over extended distances
- Durability: Extreme environment rated
Packaging
- Spool Size: 1000ft wooden spool
- Design: Sturdy spool for outdoor deployment and tangle-free pulls
Compliance & Certifications
- Standards: ANSI/TIA-568.2-D, ISO/IEC 11801
- Rating: Outdoor, Direct Burial
- Burial Approved: Direct burial rated
- Environmental: UV-resistant, weatherproof