C14 to C15 Power Cord, 14/3 SJT, 15 A 125 V, Black, 3 to 10 ft (PWRAP)
Couldn't load pickup availability
A server or a switch with a notched C16 inlet, the one a C13 cord won't seat in, still has to be fed from the PDU, and this is the cord for it: a C14 male plug for the PDU's, the UPS's, or an extension's C13 outlet, a C15 female connector for the equipment, on 14/3 SJT rated 15 A at 125 V AC for 1875 W. The C15 is the C13 with a notch cut in it, built for equipment whose power supply runs hot, and it fits a C16 inlet and an ordinary C14 inlet alike, so this cord replaces a C13 to C14 jumper anywhere in the rack and is the only one that works on the hot-inlet gear. The 14 AWG conductors carry a full 15 A load without the voltage drop or the heat of a lighter cord, and the 3, 6, and 10 ft lengths cover a jumper to the PDU in the same rack, a run to a UPS below, or a reach into the next cabinet. Black, UL approved, RoHS compliant. For the same C15 from a wall receptacle, the PWRAD 5-15P to C15; for the C13 gear in the rack, the PWRAO 16/3 and PWRAU 18/3 C13 to C14 jumpers.
Features
- IEC-320 C14 to IEC-320 C15. Male C14 plug to notched female C15 connector, 3 conductor grounded.
- 15 A, 125 V AC, 1875 W. Rated for a full 15 A load.
- 14 AWG, 3 conductor. SJT jacket, black.
- 3, 6, and 10 ft. In-rack jumper to cross-cabinet run.
- UL approved, RoHS compliant.
Where It Fits
It suits data center and network techs feeding servers, enterprise switches, and storage arrays with C16 inlets from a rack PDU, telecom and carrier racks with hot-swap redundant supplies that take the notched connector, high-wattage workstation and rendering builds on a rack power strip, industrial control cabinets with a C16-inlet controller fed from a UPS, anyone who has pushed a C13 cord at a notched inlet and wondered why it won't go, and a rack that already has the PDU, the C13 to C14 jumpers, and the cable management from the power and rack collections. For the same connector from a wall receptacle, the PWRAD 5-15P to C15; for C20 inlets, the PWRAR C19 to C20 and PWRAQ C14 to C19; for the lighter C13 gear, the PWRAO 16/3 and PWRAU 18/3 jumpers.
Good to Know
The C15 fits both a C16 inlet, the one with the ridge, and an ordinary C14 inlet, so this cord can stand in for a C13 to C14 jumper on any equipment in the rack, while a C13 cord cannot stand in for it on a C16 inlet; the notch is there so the hot-inlet gear only gets the cord rated for it. The cord goes between a PDU or a UPS and a piece of equipment, not into a wall: a C14 plug fits a C13 outlet and nothing on a wall, and the PWRAD is the wall-plug version of the same cord. The 15 A rating is the cord's maximum and also the rating of the C13 outlet feeding it on a UL-rated PDU, so check the outlet's marking against the equipment's nameplate and keep the total on the PDU within its breaker. SJT is a 300 V thermoplastic jacket rated for indoor junior hard service; it's for the inside of a rack, not for outdoors or for being walked on. A 14 AWG cord is stiff compared to the 18 AWG jumpers, so give it room to bend behind the chassis and pick the length that reaches with a gentle loop, since a 3 ft cord stretched tight between a PDU and a server will pull out of the inlet when the server slides forward on its rails. Seat both ends fully; a connector that's half seated on a 15 A load runs warm.
Specifications
| Spec | Detail |
|---|---|
| Model | PWRAP-3BLK (3 ft, black; other lengths by suffix) |
| Series | PWRAP |
| Type | Power cord, C14 to C15 |
| Connector A | IEC-320 C14, male plug |
| Connector B | IEC-320 C15, notched female connector |
| Rating | 15 A, 125 V AC, 1875 W |
| Conductors | 14 AWG, 3 conductor, grounded |
| Cable Type | SJT |
| Color | Black |
| Compliance | UL approved, RoHS |
| Lengths | 3, 6, and 10 ft |