CAT7 CMR Riser Cable 1000ft - S/FTP Dual-Shielded, 23AWG Solid Copper 10G

SKU: C7SHDIN-1000BLU
Regular price $430.00
Color
Payment methods
  • Ach Direct Debit
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Ships on a wooden spool. These reels are large and heavy, so shipping costs more than a standard parcel and the shipment requires a receiver who can accept and handle it. Confirm your delivery location can accommodate a shipment of this size and weight before placing your order.

Delivery refusal policy. Because of the size and weight of this item, refused deliveries incur significant freight costs. If a shipment is refused or the receiver cannot accept it, you are responsible for both outbound and return freight, plus any restocking fee.

This is the cable to pull when you want the most shielding and the most headroom copper can give a 10G run. Cat7 is the ISO Class F specification, rated to 1000 MHz, twice Cat6A, and it's always built S/FTP: each of the four pairs wrapped in its own aluminum-mylar foil, with a tinned copper braid around all four. The per-pair foil takes crosstalk between the cable's own pairs almost out of the picture; the braid handles the low-frequency fields from power distribution and heavy machinery and gives the shield a low-resistance path to ground. In a hospital riser, a broadcast plant, or a factory control room, that's the difference between a 10G link that passes certification and one that doesn't.

The 23 AWG solid copper conductors have HDPE insulation, and the flame-retardant PVC jacket is CMR riser rated. It comes on a 1000 ft wooden spool with footage markings on the jacket.

Features

  • 10GBase-T over a full 100 m channel, with the margin to spare. It also runs 5G, 2.5G, and 1G links, and works with Cat6A, Cat6, and Cat5e equipment.
  • 1000 MHz, ISO/IEC 11801 Class F. Twice the bandwidth of Cat6A, for the cleanest 10G channel copper can deliver and headroom for what comes after.
  • S/FTP double shielding. Foil on every pair plus an overall tinned copper braid, for the most interference rejection and the lowest crosstalk available in a riser cable.
  • Drain wire. It gives the shield layers a path to ground at the patch panel.
  • CMR riser rated. Rated for riser runs between floors as well as general in-wall and ceiling use.
  • 23 AWG solid bare copper. Full-gauge solid conductors for the lowest loss over a full channel and the least voltage drop on PoE runs. No copper-clad aluminum.
  • HDPE insulation. Tight, consistent pair twists for crosstalk control.
  • Sequential footage markings. You can see what's left on the spool and cut runs to length without a tape.
  • 1000 ft wooden spool. Standard TIA-568 pair colors inside.
  • Three jacket colors. Blue, gray, and white.

Where It Fits

It suits 10G risers and backbones in hospitals and imaging centers, broadcast and post-production facilities, manufacturing plants with drives, welders, and large motors, research labs with sensitive instruments, data center rows with dense trays, and any permanent link where the spec calls for Class F or the noise floor has beaten a foil-only Cat6A.

Good to Know

Cat7 is an ISO standard, not a TIA one, and it was written around its own connectors (GG45 and TERA). Terminated on standard RJ45 jacks and patch panels, which is how nearly everyone installs it, the channel certifies as Cat6A: 10G over 100 m, with the S/FTP shielding as the reason to choose it. So buy this cable for the shielding and the margin, not for speeds beyond 10G on RJ45. A shield only works when it's grounded: terminate on shielded Cat6A or Cat7 jacks that bond to the braid, ground it at one end, normally the patch panel, and use shielded patch cords and switch ports so the shield is continuous end to end. Terminating S/FTP takes longer than F/UTP, since each pair's foil has to be stripped back and the braid folded and clamped, so allow for it in the labor estimate. CMR covers risers and general indoor spaces but not plenum air-handling ceilings. Plan for a bend radius of about four times the cable diameter. For moderate interference, the foil-only shielded Cat6A riser does the job for less and terminates faster. Solid conductors are for permanent runs; terminate on jacks and patch panels, not crimped plugs.

Specifications

Spec Detail
Series C7SHDIN
Category Cat7, ISO/IEC 11801 Class F
Bandwidth 1000 MHz
Shielding S/FTP (aluminum-mylar foil on each pair plus overall tinned copper braid, with drain wire)
Conductors 23 AWG solid bare copper, 4 pairs / 8 conductors
Insulation HDPE
Pair Colors TIA-568: blue, orange, green, brown
Jacket Flame-retardant PVC, CMR rated
Outer Diameter 7.5 ± 0.5 mm
Footage Markings Sequential, printed on jacket
Packaging 1000 ft (305 m) wooden spool
Colors Blue, Gray, White
Compliance RoHS