5-15P to C15 Power Cord, 14/3 SJT, 15 A 125 V, Black, 6 and 10 ft (PWRAD)
Couldn't load pickup availability
Some equipment has a power inlet with a small ridge across it, and an ordinary C13 cord won't go in; that inlet is a C16, it's there because the power supply runs hot, and the cord it takes is this one. This computer power cord runs from a standard NEMA 5-15P three-prong wall plug to a C15 connector, the notched version of the C13 that fits a C16 inlet and a C14 inlet alike, on 14/3 SJT cable rated 15 A at 125 V AC for 1875 W. The 14 AWG conductors carry a full 15 A load without the voltage drop of a lighter cord, which is what a server, a high-wattage workstation, a big switch, or a laser printer wants from the wall, and the 6 and 10 ft lengths let the cord be the length the run needs rather than the length that came in the box. It plugs straight into any standard North American receptacle and works with most American equipment. Black, UL approved, RoHS compliant.
Features
- NEMA 5-15P to IEC-320 C15. Standard 3-prong wall plug to notched C15 connector.
- 15 A, 125 V AC, 1875 W. Rated for a full 15 A circuit.
- 14 AWG, 3 conductor. SJT jacket, black.
- 6 and 10 ft. Order the length the run needs and keep the cable neat.
- UL approved, RoHS compliant.
Where It Fits
It suits IT and data center techs powering a server, a storage array, or an enterprise switch with a C16 inlet from a wall receptacle where there's no PDU, engineering and rendering shops feeding a high-wattage workstation, offices replacing the cord on a laser printer or a copier that has the notched inlet, broadcast, audio, and video racks with a hot-running amplifier or processor, home theater and projector installs that need a 10 ft cord to reach the outlet, anyone who has tried to push a C13 cord into a notched inlet and wondered why it won't seat, and a rack that already has the PDU, the C13 to C14 jumpers, and the cable management from the power and rack collections. For a PDU-to-equipment jumper, the PWRAO C13 to C14 cord.
Good to Know
The C15 is the C13 with a notch cut in it: it fits a C16 inlet, which is the one with the ridge and is used on equipment whose power supply runs hot, and it also fits an ordinary C14 inlet, so this cord replaces a 5-15P to C13 cord anywhere and a C13 cord replaces it nowhere. A 15 A, 1875 W rating is the full capacity of a standard 15 A branch circuit, so a cord this size on a shared office circuit is fine for one server or workstation and not for several at once; the circuit, not the cord, is the limit. SJT is a 300 V thermoplastic jacket rated for indoor junior hard service; it's for an office, a rack, or a studio, not for outdoors or for being walked on. The 5-15P plug is the standard grounded North American plug, so there's no adapter; route the cord so the plug seats fully in the receptacle and the C15 seats fully in the inlet, since a half-seated connector on a 15 A load runs warm. Pick the length that reaches with a gentle loop and no more.
Specifications
| Spec | Detail |
|---|---|
| Model | PWRAD-6BLK (6 ft, black; other lengths by suffix) |
| Series | PWRAD |
| Type | Computer power cord, 5-15P to C15 |
| Connector A | NEMA 5-15P, 3-prong grounded plug |
| Connector B | IEC-320 C15, notched female connector |
| Rating | 15 A, 125 V AC, 1875 W |
| Conductors | 14 AWG, 3 conductor, grounded |
| Cable Type | SJT |
| Color | Black |
| Compliance | UL approved, RoHS |
| Lengths | 6 and 10 ft |