12-Splice Fiber Splice Tray, Aluminum, GR-769, 7 × 4.75 in (FSTA-1001)
Couldn't load pickup availability
This is a 12-splice fiber splice tray in aluminum, 7 in long, 4.75 in wide, and 0.5 in tall, built to Telcordia GR-769, and it's made in the USA. It holds 12 single fusion splices in its standard layout, 8 mechanical splices, or 48 mass fusion splices when it's set up for ribbon cable, with splice holders that mount left- or right-handed so the fibers can enter from either side, and it comes with adhesive-backed fiber insert holders. The aluminum body is stiff, sheds heat, and doesn't corrode. It's the standard-footprint 12-fiber tray in metal, for a patch panel, a fiber distribution unit, or a splice closure where the slot is cut for the common 7 by 4.75 in size. It's sold individually. For the same tray in plastic, the FSTA-1002; for a smaller 12-splice tray for a cramped wall box, the FSTA-1003; for 24 splices in aluminum, the FTSA-2008, FTSA-2001, and FTSA-2002; for the pigtails that get spliced in it, the 12-fiber PGTLC12-SM, PGTSC12-SM, and PGTST12-SM; for the sleeves, the 60 mm FSTA-1005 and 40 mm FSTA-1004.
What's in the Box
- 12-splice aluminum fiber splice tray
- Adhesive-backed fiber insert holders
Features
- Made in the USA.
- 12 single fusion splices. Or 8 mechanical splices, or 48 mass fusion splices on ribbon fiber.
- Telcordia GR-769 compliant.
- Left- or right-handed holders. Fibers can enter the splice holders from either side.
- Aluminum. Rigid, sheds heat, and corrosion resistant.
- 7 × 4.75 × 0.5 in. The standard tray footprint; for patch panels, fiber distribution units, and splice closures.
- Adhesive-backed insert holders included.
- Sold individually.
Where It Fits
It suits a carrier or utility drop point where the spec calls for GR-769 and a metal tray, and a 12-fiber cable or a 48-fiber ribbon gets its own tray in a closure or a distribution unit. It suits a patch panel or a fiber distribution unit with standard tray slots in a telecom room that runs warm or sees a lot of hands. Splicing crews on ribbon plant use it for the 48-fiber mass fusion layout in a small tray, and so do installers replacing a cracked plastic 12-fiber tray with one that will outlast the box. An industrial site where the fiber closure sits near heat or vibration is a candidate. It goes with the single-mode and multimode pigtails, the splice sleeves, the fusion splicer, and the wall-mount and rack-mount enclosures from the fiber collections. For the same footprint in plastic, the FSTA-1002. For a smaller 12-fiber tray, the FSTA-1003. For 24 splices in aluminum, the FTSA-2008, FTSA-2001, or FTSA-2002. For 36 in aluminum, the FTSA-3001. For 12-fiber pigtails, the PGTLC12-SM, PGTSC12-SM, and PGTST12-SM. For the splice sleeves, the FSTA-1005 and FSTA-1004.
Good to Know
Pick the layout before you splice: 12 single fusion sleeves is the standard count, 8 if the splices are mechanical, since those are bigger, and 48 only with ribbon cable and a mass fusion splicer, where each ribbon sleeve carries 12 fibers. A single-fiber splicer can't make a ribbon splice, so the 48 figure is for crews with the ribbon kit, not a way to get 48 loose fibers into one tray; and the three counts are alternatives, not a total. The holders mount left- or right-handed, so set them up to match the direction the cable and the pigtails enter the tray before you start, rather than fighting the routing afterward. Measure the slot before you order: 7 by 4.75 in is the common tray footprint, so this one fits most distribution units and closures built for standard trays, where the 6 by 2.75 in FSTA-1003 is for the small boxes that won't take it. GR-769 is the Telcordia standard for splice trays and closures, which matters on a carrier or a utility job where the spec calls for it, and doesn't change how the tray is used. Match the sleeve to the holder, since the tray is sized for standard single-fiber fusion sleeves and for ribbon sleeves in the mass fusion layout; check which length the holders take before you buy a pack. Use the adhesive-backed insert holders to fix the inserts where the tray or the enclosure has no slot, on a clean, dry, flat surface, and give the adhesive time to set before loading fiber. Route the fibers around the tray in the direction the guides allow, with a full loop of slack on each side of the splice so a sleeve can be redone later without pulling the cable, and keep every bend larger than the fiber's minimum radius; a metal edge is less forgiving than a plastic one if a fiber is pulled across it, so dress the fibers inside the guides and not over the rim. Anchor the incoming buffer tubes or ribbons and the pigtail jacket at the tray's edge so the splices aren't carrying any weight. Splice in the standard color sequence, blue through aqua for fibers 1 through 12, and label the tray on the as-built.
Specifications
| Spec | Detail |
|---|---|
| Model | FSTA-1001 |
| Series | FSTA |
| Type | Fiber splice tray, fusion, mechanical, and mass fusion splices |
| Capacity | 12 single fusion splices (standard); 8 mechanical splices; 48 mass fusion splices on ribbon |
| Splice Holders | Left- or right-handed mounting |
| Dimensions | 7 × 4.75 × 0.5 in (178 × 121 × 13 mm), L × W × H |
| Material | Aluminum, corrosion resistant |
| Standards | Telcordia GR-769 |
| Included | Adhesive-backed fiber insert holders |
| Fits | Patch panels, fiber distribution units, splice closures |
| Country of Origin | USA |
| Shipping | Usually ships in 1 business day |
| Quantity | Sold individually |