{"product_id":"22-2-shielded-plenum-security-alarm-cable-cmp-rated","title":"22 AWG 2-Conductor Shielded Plenum Alarm Cable - CMP Rated, EMI Protection, 1000ft","description":"\u003cp\u003ePremium shielded plenum-rated 2-conductor security alarm cable engineered for high-reliability installations requiring both EMI protection and fire safety compliance. This USA-made cable features two 22-gauge stranded bare copper conductors with 7 strands each, protected by aluminum foil shielding and housed in a low-smoke CMP-rated white jacket. Designed for demanding security systems, intercoms, audio applications, and power-limited controls where electromagnetic interference protection and plenum rating are both essential.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e22 AWG 2-Conductor Design\u003c\/strong\u003e - Ideal wire gauge for standard security and control applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Foil Shielding\u003c\/strong\u003e - Superior protection against electromagnetic interference (EMI\/RFI)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-Strand Bare Copper Conductors\u003c\/strong\u003e - Excellent flexibility and reliable signal transmission\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCMP\/CL3P Plenum Rated (FT6)\u003c\/strong\u003e - Approved for HVAC plenums and air-handling spaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Smoke PVC Construction\u003c\/strong\u003e - Enhanced fire safety with minimal toxic smoke emission\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSequential Footage Marking\u003c\/strong\u003e - Precise measurement for accurate installation planning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrint Legend for Identification\u003c\/strong\u003e - Cable markings save valuable installation time\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETL Listed \u0026amp; RoHS Compliant\u003c\/strong\u003e - Meets strict safety and environmental standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite Low-Smoke Jacket\u003c\/strong\u003e - Clean, professional appearance for visible installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMade in USA\u003c\/strong\u003e - Premium domestic manufacturing quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eIdeal Applications\u003c\/h4\u003e\n\u003cp\u003ePerfect for shielded plenum installations in commercial and residential buildings:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Reliability Security \u0026amp; Alarm Systems\u003c\/li\u003e\n\u003cli\u003eCommercial Access Control Systems\u003c\/li\u003e\n\u003cli\u003eProfessional Intercom Systems\u003c\/li\u003e\n\u003cli\u003eAudio Distribution Systems\u003c\/li\u003e\n\u003cli\u003ePower-Limited Control Circuits\u003c\/li\u003e\n\u003cli\u003eBuilding Automation in EMI Environments\u003c\/li\u003e\n\u003cli\u003eCritical Infrastructure Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Material:\u003c\/strong\u003e Stranded Bare Copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Gauge:\u003c\/strong\u003e 22 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Conductors:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrands per Conductor:\u003c\/strong\u003e 7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner Conductor Diameter:\u003c\/strong\u003e 1.2mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Insulation:\u003c\/strong\u003e Low-Smoke PVC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Aluminum Foil (100% Coverage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Diameter (Nominal OD):\u003c\/strong\u003e 3.35mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 0.38mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJacket Material:\u003c\/strong\u003e Low-Smoke PVC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJacket Color:\u003c\/strong\u003e White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Performance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 75°C (167°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCenter Resistance:\u003c\/strong\u003e 21.20 Ω\/km\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCertifications \u0026amp; Compliance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlenum Rating:\u003c\/strong\u003e CMP (Communications Plenum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire Rating:\u003c\/strong\u003e FT6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Ratings:\u003c\/strong\u003e CL3P, FPLP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListings:\u003c\/strong\u003e ETL Listed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e RoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePackage Details\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 1000 feet per spool\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Made in USA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecial Features:\u003c\/strong\u003e Print legend for easy identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhy Choose Shielded 22\/2 Plenum Cable?\u003c\/h4\u003e\n\u003cp\u003e✓ \u003cstrong\u003eDual Protection\u003c\/strong\u003e - Combines EMI shielding with plenum fire safety rating\u003cbr\u003e✓ \u003cstrong\u003eFire Code Compliant\u003c\/strong\u003e - CMP\/FT6 rating meets stringent requirements for air-handling spaces\u003cbr\u003e✓ \u003cstrong\u003eEMI\/RFI Shield\u003c\/strong\u003e - Aluminum foil protects against electrical interference and false alarms\u003cbr\u003e✓ \u003cstrong\u003eLow Smoke Safety\u003c\/strong\u003e - Special insulation reduces toxic emissions during fire emergencies\u003cbr\u003e✓ \u003cstrong\u003eProfessional Quality\u003c\/strong\u003e - Print legend markings save installation time and reduce errors\u003cbr\u003e✓ \u003cstrong\u003eCost-Effective\u003c\/strong\u003e - Optimal balance of performance and price for standard applications\u003cbr\u003e✓ \u003cstrong\u003eVersatile Use\u003c\/strong\u003e - Single cable suitable for security, intercom, and control applications\u003c\/p\u003e\n\u003ch4\u003eFT6 Fire Rating Explained\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eFT6 Rating\u003c\/strong\u003e is the Canadian equivalent of the CMP plenum rating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame fire safety performance\u003c\/strong\u003e as CMP\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRecognized in Canadian building codes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully interchangeable\u003c\/strong\u003e with CMP-rated cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow flame spread\u003c\/strong\u003e and smoke generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for plenum spaces\u003c\/strong\u003e in both US and Canadian installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommon Use Cases\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Office Buildings:\u003c\/strong\u003e Single-zone security in plenum spaces near computers and office equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetail Stores:\u003c\/strong\u003e Point-of-sale security with EMI protection from electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Centers:\u003c\/strong\u003e Security sensors near high-EMI server and networking equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHealthcare Facilities:\u003c\/strong\u003e Medical facility security near diagnostic and treatment equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEducational Institutions:\u003c\/strong\u003e Classroom or office security in plenum ceiling environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Facilities:\u003c\/strong\u003e Security systems in light manufacturing with electrical interference\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinancial Institutions:\u003c\/strong\u003e Secure areas requiring both fire safety and EMI protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGovernment Buildings:\u003c\/strong\u003e Critical spaces with strict fire and interference requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Offices:\u003c\/strong\u003e Attorney, accounting, or medical offices with security needs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Buildings:\u003c\/strong\u003e Basic security integration in intelligent building systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePrint Legend Benefits\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTime-Saving Identification:\u003c\/strong\u003e The cable jacket includes printed information such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWire gauge and conductor count (22 AWG 2C)\u003c\/li\u003e\n\u003cli\u003eShielding type (SHIELDED)\u003c\/li\u003e\n\u003cli\u003eFire rating (TYPE CL3P\/FPLP, TYPE CMP)\u003c\/li\u003e\n\u003cli\u003eCertification marks (c(ETL)us)\u003c\/li\u003e\n\u003cli\u003eSequential footage marking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick Verification:\u003c\/strong\u003e Instantly confirm correct cable during installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode Compliance:\u003c\/strong\u003e Inspectors can easily verify proper cable type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuture Service:\u003c\/strong\u003e Technicians can identify cable specifications without testing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Simplifies creating as-built drawings and documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Prevention:\u003c\/strong\u003e Reduces chances of installing wrong cable type\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEMI Protection Explained\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Sources of Electromagnetic Interference:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluorescent lighting and ballasts\u003c\/li\u003e\n\u003cli\u003eElectric motors and HVAC equipment\u003c\/li\u003e\n\u003cli\u003eComputer and networking equipment\u003c\/li\u003e\n\u003cli\u003eRadio frequency (RF) transmitters\u003c\/li\u003e\n\u003cli\u003ePower transformers and inverters\u003c\/li\u003e\n\u003cli\u003eVariable frequency drives (VFDs)\u003c\/li\u003e\n\u003cli\u003eElevators and escalators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHow EMI Affects Unshielded Security Cables:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFalse alarms from sensor circuits\u003c\/li\u003e\n\u003cli\u003eIntermittent signal degradation\u003c\/li\u003e\n\u003cli\u003eUnreliable device communication\u003c\/li\u003e\n\u003cli\u003eSystem malfunctions and nuisance trips\u003c\/li\u003e\n\u003cli\u003eIncreased service calls and maintenance costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Solution:\u003c\/strong\u003e Aluminum foil shielding intercepts these electromagnetic waves, preventing them from inducing currents in the signal conductors. Proper grounding allows the shield to safely divert interference to ground.\u003c\/p\u003e\n\u003ch4\u003eWhen to Choose This Cable\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-zone security installations in plenum spaces with EMI concerns\u003c\/li\u003e\n\u003cli\u003eUpgrading existing systems experiencing interference-related false alarms\u003c\/li\u003e\n\u003cli\u003eCommercial buildings requiring both fire safety and EMI protection\u003c\/li\u003e\n\u003cli\u003eNew construction with plenum space requirements and electrical noise\u003c\/li\u003e\n\u003cli\u003eProfessional installations where reliability is critical\u003c\/li\u003e\n\u003cli\u003eCode-required plenum installations in EMI-sensitive environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConsider Alternatives If:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple zones needed (consider 22\/4 or 22\/6 shielded plenum)\u003c\/li\u003e\n\u003cli\u003eMinimal EMI concerns (22\/2 unshielded plenum may suffice)\u003c\/li\u003e\n\u003cli\u003eVery long runs required (consider 18\/2 shielded plenum for heavy-duty)\u003c\/li\u003e\n\u003cli\u003eNon-plenum spaces (CMR riser shielded may be more cost-effective)\u003c\/li\u003e\n\u003cli\u003eExtreme EMI environment (consider double-shielded or twisted pair options)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBuilding Code Compliance\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eBefore Installation, Verify:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLocal fire marshal requirements for plenum spaces\u003c\/li\u003e\n\u003cli\u003eBuilding code specifications for fire-rated cable\u003c\/li\u003e\n\u003cli\u003eNEC article compliance for specific application\u003c\/li\u003e\n\u003cli\u003eManufacturer requirements for security\/fire alarm panels\u003c\/li\u003e\n\u003cli\u003eJurisdictional requirements for shielded cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis cable meets or exceeds:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNational Electrical Code (NEC) Articles 760, 800, 725\u003c\/li\u003e\n\u003cli\u003eCMP plenum requirements for air-handling spaces\u003c\/li\u003e\n\u003cli\u003eFT6 Canadian fire safety standards\u003c\/li\u003e\n\u003cli\u003eETL safety certification requirements\u003c\/li\u003e\n\u003cli\u003eRoHS environmental compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways consult with local authorities having jurisdiction (AHJ) and follow manufacturer specifications for complete code compliance.\u003c\/p\u003e","brand":"Patch Cords Online","offers":[{"title":"Default Title","offer_id":51764278624578,"sku":"SEC019-1000WHI","price":129.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2175\/5714\/files\/SEC019-1000WHI.png?v=1767482363","url":"https:\/\/patchcordsonline.com\/products\/22-2-shielded-plenum-security-alarm-cable-cmp-rated","provider":"Patch Cords Online","version":"1.0","type":"link"}